Description: FDA CE Portable Vital Signs ICU CCU Patient Monitor CMS8000 Introduction The monitor has abundant functions that can be used for clinical monitoring with adult, pediatric and neonate. Users may select different parameter configuration according to different requirements. The monitor, power supplied by 100-240V~,50/60Hz, adopts 12.1'' color TFT LCD displaying real-time date and waveform. It can synchronously display eight-channel waveform and full monitoring parameters equipped with an optional 48mm thermal recorder. The monitor can be connected to the central monitoring system via wire or wireless network to form a network monitoring system. This device can monitor such parameters as ECG, RESP, NIBP, SpO2, and dual-channel TEMP, etc. It integrates parameter measurement module, display and recorder in one device to form a compact and portable equipment. Its replaceable internal battery brings lot of convenient for patient moving. Functions Standard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP 1)ECG Heart rate(HR) ECG waveform Arrhythmia and ST-segment analysis 2)RESP Respiration rate(RR) Respiration waveform 3)SpO2 Oxygen saturation(SpO2) Plethysmogram(PLETH) waveform Pulse rate(PR) Bar graph 4)NIBP Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN) 5)TEMP T1, T2, TD 6)IBP(optional) CH1:SYS,DIA,MAP CH2:SYS,DIA,MAP IBP waveform 7)CO2 EtCO2(optional) InsCO2:Inspired Minimum CO2 AwRR:Air Way Respiration It has abundant functions, such as audible and visual alarm, trend data storage and output, NIBP measurement, alarm event marking and drug concentration calculation, etc. Features 1)12.1'' TFT color LCD, multi-language interface(Simplified Chinese, Traditional Chinese, English, French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian, Kazakh, Polish, Czech). 2)Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection. 3)All-round monitor for adult, pediatric and neonate. 4)With standard interface, oxygen graph, trend graph, big character interface and view bed, convenient to observe. 5)Finish all operations by keys and knobs. 6)Maximum 8-channel waveform synchronous display. 7)Display 7-lead ECG waveform on one screen, cascade ECG waveform display 8)Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling. 9)Heart rate variability (HRV) analysis function 10)NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data. 11)Review for 71 alarm events of all parameters and 60 arrhythmia alarm events. 12)Drug concentration calculation and titration table functions. 13)One-touch printing of trend graph 14)Connect to Central Monitoring System by 3G, Wi-Fi or wired mode. 15)AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring. 16)Anti-high frequency surgical unit, defibrillation-proof (special leads are necessary). Performance ▲ECG Lead mode: 3-lead or 5-lead Lead selection: I, II, III, aVR, aVL, aVF, V Waveform: 5-lead, dual-channel 3-lead, single-channel Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s HR: Measurement and alarm range: 15~350 bpm Accuracy: ±1 % or ±1 bpm, whichever is greater Alarm accuracy: ± 2 bpm Resolution: 1 bpm ST-segment monitoring: Measurement and alarm range: -2.0 mV ~ +2.0 mV Accuracy: -0.8 mV~+0.8 mV ±0.04 mV or ±10%, whichever is greater Other range: unspecified Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC Pacemaker: yes ▲RESP Method: R-F(RA-LL) Impedance Respiration rate: Measurement and alarm range: 0~150 rpm Resolution: 1 rpm Measurement accuracy: ±2 rpm Alarm accuracy: ±3 rpm Apnea alarm: 10~40s Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s ▲NIBP Method: Oscillometry Mode: Manual/AUTO/STAT Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes Measurement period in STAT mode: 5 minutes Measurement and alarm range: 10 ~ 270 mmHg Resolution: 1 mmHg Cuff pressure accuracy: ±3 mmHg Measurement accuracy: Maximal mean deviation: ±5 mmHg Maximal standard deviation: 8 mmHg Over-pressure protection: Adult mode: 297±3 mmHg Pediatric mode: 240±3 mmHg Neonatal mode: 147±3 mmHg ▲SpO2 Measurement and alarm range: 0 ~ 100% Resolution: 1% Measurement accuracy: 70%~100%: ±2%; 0%~69%: unspecified ▲PR Measurement and alarm range: 30 ~ 250 bpm Measurement accuracy: ±2 bpm or ±2%, whichever is greater ▲TEMP Channel: dual-channel Measurement and alarm range: 0 ~ 50℃ Resolution: 0.1 ℃ Accuracy: ±0.1 ℃ ▲EtCO2(optional) Method: Sidestream or Mainstream Measuring Range: 0~150mmHg Resolution: 0~69 mmHg, 0.1 mmHg 70~150 mmHg, 0.25 mmHg Accuracy: 0~40 mm Hg ±2 mm Hg 41~70 mm Hg ±5% 71~100 mm Hg ±8% 101~150 mm Hg ±10% AwRR Range: 2~150 rpm AwRR Accuracy: ±1BPM Apnea Alarm: Yes ▲IBP(optional) Channel: dual-channel Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measuring and Alarm Range: -10~300 mmHg Resolution 1 mmHg Accuracy: ±2% or 1mmHg, whichever is greater ▲Power supply: 100-240V~, 50/60Hz ▲Safety classification: Class I, type CF defibrillation-proof applied part Accessories 1)Adult fingertip SpO2 probe (5-pin) 2)Adult NIBP cuff 3)NIBP extension tube 4)ECG lead cable 5)ECG electrode 6)Temperature probe 7)Power cord 8)User Manual Physical characteristic Dimension: 314 mm(L) × 145 mm(W) × 264 mm(H) Weight: 3.9 Kg(without Rolling Stand) Buy Safe Product! The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, We will verify your status as an authorized purchaser of this item before shipping of the item.Shipment 1. We will ship the item within 48 hours after receiving your payment, please kindly leave your detail shipping address and telephone number, both are very important for the shipment,thank you. 2.We will upload the tracking number after shipment,you can search from both ebay and paypal.You can track online.3. If you haven't received the item after 2 weeks of your payment, please contact me immediately! Terms of Sale 1.If you have a defective item, you want to return or discount. Please contact us within 60 days from you receive the shipment.All return items must be returned with it's original packaging and accessories. Customer is responsible for shipping charges on returned items.2.we will refund the money to you when we get the return items. Or replace item for you. We will deal with the refund in 2 business days when we get the info from you.Please read our trade Policy before buy , if you don't agree our trade policy please don't buy it. Only English user manual,if you need any other language,please contact us!
Price: 599 USD
Location: Elk Grove Village, Illinois
End Time: 2024-08-07T07:26:24.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 60 Days
Refund will be given as: Money Back
Return policy details:
Optional Parameters: ETCO2,IBP,Thermal Printer
Brand: CON-TEC
Screen Dimensions: 12.1
Support Language: French, German, Italian, Turkish, etc.
Screen: 12.1 Inch Color TFT LCD
Battery: Built-in rechargeable lithium battery
Model: CMS8000
MPN: 69450401
Country/Region of Manufacture: China
Monitor Parameters: Blood Pressure - NIBP, ECG, O2 - SpO2, Respiratory Rate, Temperature