Description: Please refer to the section BELOW (and NOT ABOVE) this line for the product details - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Title:Horizontal Convective Boiling Of R134a, R1234yf/R134a, And R1234ze(E) Within A Micro-Fin Tube With Extensive Measurement And Analysis DetailsISBN13:9781496030818ISBN10:1496030818Author:Nist (Author)Description:This Report Presents Local Convective Boiling Measurements In A Micro-Fin Tube For R134a And Two Low Global Warming Potential (Gwp ) Refrigerants: R1234yf R134a, 5644 % Mass And R1234ze(E) Water Heating Either In Counterflow Or In Parallel Flow With The Test Refrigerant Was Used To Vary The Heat Flux For A Given Quality The Heat Transfer Coefficient Of The Three Test Fluids Were Compared At The Same Heat Flux, Saturated Refrigerant Temperature, And Refrigerant Mass Flux Using An Existing Correlation From The Literature The Resulting Comparison Showed That Refrigerant R134a Exhibited The Highest Heat Transfer Performance In Large Part Due To Its Higher Thermal Conductivity As Compared To The Tested Low-Gwp Refrigerants For The Example Case Presented Here, The Heat Transfer Coefficient For R1234yf R134a (5644) Remains Within 5 % Of The Heat Transfer Coefficient For R134a, Having Essentially Identical Performance For Qualities Less Than 30 % The Heat Transfer Coefficient For R1234ze(E) Is Roughly 700 Kw, K-1, M-2 (Approximately 14 %) Less Than That Of R134a For Qualities Greater Than 30 % The Smaller Heat Transfer Coefficient Of R1234ze(E) As Compared To That Of R134a Is Primarily Due To The 11 % Smaller Thermal Conductivity And The 21 % Smaller Reduced Pressure As Compared To R134a At This Test Temperature The Measurements Are Important As Part Of The Evaluation Of Low-Gwp Replacement Refrigerants For R134a In Unitary Refrigeration And Air-Conditioning Equipmen Binding:Paperback, PaperbackPublisher:CREATESPACEPublication Date:2014-02-24Weight:0.37 lbsDimensions:0.13'' H x 11.02'' L x 8.5'' WNumber of Pages:62Language:English
Price: 13.83 USD
Location: USA
End Time: 2024-08-22T08:56:52.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Return policy details:
Book Title: Horizontal Convective Boiling of R134a, R1234yf/R134a, and R1234ze Within a Micro-Fin Tube with Extensive Measurement and Analysis Details
Item Length: 11in.
Item Height: 0.1in.
Item Width: 8.5in.
Author: Nist
Format: Trade Paperback
Language: English
Topic: Energy
Publisher: CreateSpace
Publication Year: 2014
Genre: Science
Item Weight: 7.4 Oz
Number of Pages: 60 Pages