Description: Package List: Needle Tips: 2/15 20 PC 4/25 20 PC 4/35 20 PC 1. Indications For user The Easydo Activator system uses technology of sonic energy for root canal treatment. The driver work with the Hand device, motor and needle tip to provide power for tip oscillation and vibration. Evidence-based endodontics has shown that cavitation and acoustic streaming can improve debridement and the disruption of the smear layer and biofilm. The Activator helps the fluids streaming enter the Pulp Chamber, Root Canal, Lateral canal, Connection of inter-root canal and root apex to ensure deep cleaning and sterilization of root canal. It is beneficial to complete the 3D filling of the root canal and ensures long-term success. STORE HOME ALL ITEMS ABOUT US ADD TO FAVS FEEDBACK CONTACT US Store Category Orthodontic Endodontic Dental Lab Dental Handpiece & Repair Dental Mixing Dental Disposable Other STORE NEWSLETTER Add my Store to your Favorites and receive my email newsletters about new items and special promotions! Dental sonic irrigator Activator endo tips for EASYDO Handpiece root canal clean ultrasonic activatior Package List: Main Unit 1 PC Protective Barrier 100 PCS Needle Tips: 2/15 20 PC 4/25 20 PC 4/35 20 PC 1. Indications For user The Easydo Activator system uses technology of sonic energy for root canal treatment. The driver work with the Hand device, motor and needle tip to provide power for tip oscillation and vibration. Evidence-based endodontics has shown that cavitation and acoustic streaming can improve debridement and the disruption of the smear layer and biofilm. The Activator helps the fluids streaming enter the Pulp Chamber, Root Canal, Lateral canal, Connection of inter-root canal and root apex to ensure deep cleaning and sterilization of root canal. It is beneficial to complete the 3D filling of the root canal and ensures long-term success. 2. Notice 1) Remove the needle tip of EasyDO Activator. If your treatment process is over, please leave it for medical recycling. 2) Please put exhaustively discharged battery into the recycling box. 3)Do not submerge the unit in water. 4)Do not autoclave the unit. 3. Precautions 1) The EasyDO Activator system is only used by dental professionals. 2) The EasyDO Activator system is comprised of the Hand device and Activator needle tips of various sizes. If the system functions are used correctly, the equipment can maintain a normal operation. It is strictly prohibited to use non-original components, which will damage the equipment and make it unable to work normally. The original components include the Easydo activator hand device, needle tip and protective cover.The Easy smile reference number of the hand device EASYDO Activator-M10821 The reference numbers of the EasyDO Activator Needle tip M10822-015 (Small) M10822-025 (Medium) M10822-035 (Large) 3)The handle device provides three speeds sonic motor adjustment options (High, Med, Low). The speed gears switch setting adjustment is ultimately determined by the procedure to be performed, the cliniclan' experience can efficiently complete the clinical task. 4) The handle device don’t require calibration for normal use. 5) All clinical treatment should be performed with Easydo activator protective barrier sleeve that placed over the hand device. 6) In the course of treatment, we should use sterilized and individually packed needle tip, otherwise it will cause root canal infection. 7) It is necessary to use EasyDO Activator system correctly according to treatment specifications and operation manual to prevent injury to patients. 8) Improper using of the hand device may result in broken handle of the equipment and damage of internal components. 9) The EasyDO Activator needle tips and protective sleeve are intended for single-patient use only. Cross contamination may occur to the patient if needle tips and protective barriers are re-used. 4. Warranty information of EasyDO activator 1)TheEASYINSMILEcompanyprovidesuserswithqualityassurance withinoneyearfromthedateofpurchaseofthisproduct.In caseofany failureduetothedefectof Handdevice materialorproductionprocessofthemainframe withinthisyear,the EASYINSMILE companywill provideequipmentrepairorreplacementproducts. 2)Thewarrantydoesnotinclude consumablessuchasneedles, batteries,etc. 3)Iftheequipmentisdamagedduetoimproperuseandmaintenance, ormaintenance personnel repair or change of spare partswithout the authorizationofEASYINSMILE, thewarrantypolicyisinvalid. 4)Under any condition, neither EASY IN SMILE nor its affiliates are responsible for any special, incidental, or consequential liability resultingfromaviolationofthewarrantypolicy,contract,oranyother legal policy. Such damages include but are not limited to loss of investment, loss of profits, loss caused by wrong use of product functions, etc.; including but not limited to third party claims and increaseofservicecostcausedbyanyalternativeequipment,etc. 5)Warrantylimitations Contentnotcoveredbywarranty: -Needle tip -Handdevicebarrier sleeve -Damagecausedbymisuse,abuse,neglectofpromptorchange of the equipmentusage -Normalwearandotherexternalscratches,includingscratches,wear, cracks,discolorationorfade. -Batteryreplacement *Note: Iftheproductisnotusedforalongtime(twoweeksorlonger),please remove the battery. It also must be removed during transport, for example,duringdelivery 10) Properly dispose the Activator needles tip and hand device protective barriers in accordance with the local laws and regulations and environmental protection requirements.11) Dispose the battery after being used in accordance with the local laws and regulations and environmental protection requirements, when battery is exhausted. 12) The hand device must be repaired if necessary according to the direction of the manufacturer. 13) Don’t insert needle tip into the hand device. If the equipment is not used for a long time, placing the hand device into packing box is recommended. 14) Remove the battery when the hand device is not used for a long time. 15) The hand device can be kept at the temperature of 0 ℃ ~ 55 ℃, relative humidity 0% ~ 75% RH and air pressure750-1060 HPA. 16) The hand device should be keep away from strong electromagnetic interference, which may affect the performance and normal use of hand device. 17) The hand device should be kept away from portable or mobile RF communication devices, which may affect the performance of hand device . 18) The hand device could not be adjacent to or stored with other equipment. In addition, it is necessary to check regularly whether the hand device can work normally. 19)Properdisposalofthehand device isrequired whenthehand piece isdeemedno-functional inaccordancewithlocallawsandregulations. 6.Product parameters Name EasyDO Activator Model EASYDO Activator-M1082 Function Debridement / disinfection / root canal therapy Use environment Indoor environment; Temperature range: 0 ℃ ~ + 55 ℃; Relative Humidity: 0% ~ 75% RH; Air Pressure: 750-1060 HPA Power Supply DC:1.0v~1.5v Battery AA grade LR6, 1.5v mercury-free alkaline dry battery Size L 183mm * W 23mm * H43.1mmGross Weight 124g 7.Operation / Step Preparation: 1)Preparetherootcanaltoproduceafullytaperedshape. 2)FillpupchamberwithNaOCI,EDTA,orfinalrinsesoulution. 3) Select the needle tip that manually fits loosely within 2mm of the workinglength. 4) Placethebarriersleeveover thecompletelengthofthehanddevice. 5)Connecttheneedletiptothehand device withthebarrier sleeve.The activatorshouldsnaponfirmly,promotingasecureconnectionwiththe handdevice. 6) PressON/OFF button for 1 second, you can see the battery power status. If the power is enough, you can continue the treatment. If the powerisnotenough,youneedtoreplacethebattery. 7)Placetheattachedneedle tip intothepreparedrootcanal. 8)DrepresstheON/OFFbutton toactvate.Switchdefaultstohighspeed uponactivation. Depress the3-speedswitchtoselectmediumspeedor lowspeed. 9) Use a pumping action to move the hand device in short 2~3 mm verticalstrokes. 10) Hydro dynamically agitate the medical solution for about 30-60 seconds. 11) After washing, use a suction pipe to remove loose debris and sundries fromtherootcanal. 12)Repeattheabovestepsforeachdifferentrootcanaltreatment. * when the clinical procedure has been completed, remove the protective barrier sleeve, remove the needle tip and store it in themedical waste recycling box. The needle tip and protective sleeve are intendedforsingle-patientused only. Otherinstructions:iftheEasyDOActiver handdevicehasbeenworking for8minuteswithoutanyoperation,or thereisnooperationafter the equipment stops working, it will enter the state of self-protection system and power oFF. If you need it to restart , please depress the ON/OFFswitch. 8. Key points of Operation: 5.1)POWER OF BATTERY STATUS Depressthe" ON /OFF Switch"keyfor1secondtoobservethe"Power Indicator"statusaroundthebuttonof thehanddevice. 1. Ifthe"PowerIndicator"iswhite,itmeanstheactivatorsystemisin fullpowerstatus; 2. ifthe"PowerIndicator"isredandwhite,itmeansthesystemisin halfpowerstatus; 3. if the "Power Indicator" is red, it means the system is in power shortagestatus;4. Ifthe"PowerIndicator"isflashingred,itindicatesthatthesystemis onthevergeofpowerfailure. 5. Please noteifthe"powerindicator"isflashingred,pleasereplacethe battery. SHIPPING About FDA PAYMENTS & RETURNS FEEDBACK FAQ SHIPPING International Shipping to worldwide. Tracking information of your parcel is available. Import duties, taxes and charges are not included in the item price or shipping charges. These charges are the buyer's responsibility. Please check with your country's customs office to determine what these additional costs will be prior to bidding/buying. 5-7 days Of Standard SpeedPAK (Ebay Official Cooperative Carrier )from China for the USA buyers and the other countries which can provide standard Speedpark from China. If you didnt receive the item within 2 weeks, please contact us. Well check it for you. About 25-45 days in generally for the countries which can not provide Standard Speedpark shipping. Please check the shipping information online or leave us a message, if you didnt receive the parcel within 28 day. Well check it for you. We have local warehouse in the USA, AU and UK, you can go to your local website to purchase. Then we'll ship for you from the local warehouse, if they are in stock for local warehouse. About FDA The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.USA CHIEF OFFICE: EASYINSMILE(USA)INTERNATIONAL CORP.CHINA FACTORY: CHANGSHA EASYINSMILE MEDICAL INSTRUMENT CO LTDAddress: Room A501, A502, A504, Jinqiyuan Incubation Mansion, No. 229410000 ChangshaChinaPhone:0086-18373188632 PAYMENTS & RETURNS Payment: PayPal payment is easy and safe. Please make within 7 days after we accepted your offer or auction ended. Well cancel the order, if you didnt make a payment within 14 days or didnt leave us any message. Welcome to contact us, if you have any problems with the order.Returns: Returns could be accepted within 30 days after receipt of the item. Refund or replacement request is available only the requests within 1 week after parcel received & returning the item as the same condition as received. All items returned must contain all original packaging materials. Please repack the item carefully. FEEDBACK We always go for 100% customer satisfaction. Positive feedback means a lot to us. If you have any queries, please contact us via eBay. We will reply you as soon as possible. We will appreciate it if you please email us before leaving any negative feedback. If there is any problem, we can work together to resolve it. FAQ Q: Do you ship the parcel with a tracking number? A: We always ship the items with a tracking number and you can check the shipping information online. Q: Im in the US. When does the parcel come? A: About 5-7 days in generally. You can contact us to check the shipping information, if you didnt get it in 2 weeks. (Sometimes will deliver in the mail box ) Q: Im an international buyer. How long does the parcel reach my address? A: About 18-28 days in generally. You can leave us a message where you are, we can check it for you. Q: Why does the parcel return back to the sender? A: Sometimes the parcel was in the local post office for a long time and unable to delivery, or unclaimed, or an ambiguous delivery address, or wrong delivery details. The parcel will be back to us. Do not worry. If you didnt receive the parcel, we can resend or refund you as your request. Q: Why does your price more expensive than others? A: We always believe that the price fit the quality. And we believe that better quality and better service will make you and your customer more satisfied. Q: I received the wrong items. What happened? A: Please do not worry. Just leave us a message and send us a photo about items and shipping label. Well help you. Q: The item damaged on arrival. Could you please resend/refund me? A: Yeah, friend. We can refund/resend. Not forget send us a photo to check. Q: I want to buy several items. Could you give me a discount? A: Why not? Add all the items you need to your cart, you can get a discount automatically. Q: What type of discount do you provide? A: We provide many types of discount. You can choose the one that suits you best with the following link https://www.ebay.com/sme/easyinsmiledentist2017/offers.html Featured products Dental Plaster Trap Powder Filter $259.9 BUY IT NOW WiFi Dental Intraoral Camera $119.89 BUY IT NOW Ultrasonic Sonic Activator Irrigator $150.00 BUY IT NOW Dental interproximal Enamel IPR Strips $16.99 BUY IT NOW Dental Sectional Contoured Metal Matrices $8.04 BUY IT NOW Dental Othodontic Bracket Ⅱ Roth/MBT 022 & 345 hook $90.67 BUY IT NOW Endodontic NITI Endo Rotary Files for Root Canal $108.28 BUY IT NOW Dental Pro Matrix Bands Single-Use Adjust $58.88 BUY IT NOW CATEGORIES STORE HOME About us Contact us Search CONTACT US Order before 2pm for same day despatch(Mon-Fr) STAY IN THE KNOW Trust us, you'll want to hear what we have to say Copyright © easyinsmiledentist2017. All Rights Reserved.
Price: 54.62 USD
Location: Rowland Heights, California
End Time: 2023-12-24T19:22:43.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 60 Days
Refund will be given as: Money back or replacement (buyer's choice)
Brand: Easyinsmile
MPN: Does Not Apply
Intended Use/Discipline: Dental Laboratory, Dentistry, Endodontics
Type: Endo activator
Country/Region of Manufacture: China
60 Tips free: Yes
warranty: 1 year for Main Unit
Evenly apply medicine: Yes