Description: Portable Patient Monitor NIBP SPO2 Blood Oxygen Pulse Rate CMS5100 CONTEC Newest CMS5100 Patient Monitor adopts Oscillometry for NIBP measuring, Photoelectric Oxyhemoglobin Inspection Technology combining Capacity Pulse Scanning & Recording Technology for SpO2 measuring. Systolic Pressure(SYS), Diastolic Pressure(DIA), Mean Pressure(MAP), SpO2 and Pulse rate(PR) can be accurately measured.Compact appearance, comprehensive functions, simple and convenient operation, which is applicable for hospitals, community medical treatment and family. Features■Be applicable for adult, pediatric and neonatal for all-round monitoring, easy operation and high cost performance.■Be applicable for medicine, surgery, operating room, ICU/CCU, emergency room, obstetrics and gynecology, pediatrics.Built-in rechargeable Li-polymer battery for uninterrupted monitoring.■Compact and flexible appearance, easy for carrying and be suitable for indoor and outdoor(in ambulance) monitoring.■With user-friendly interface.■Display with 2.8'' (320×240) color TFT LCD and red and yellow highlight LED.■Visual and audible alarm for Systolic Pressure(SYS), Diastolic Pressure(DIA), Mean Pressure(MAP), SpO2 and Pulse rate(PR), and upper and lower limit of alarm can be set.■Unique Flash memory, storage for up to 2000 NIBP data and 30000 SpO2 data.■Convenient and quick in inquiring measurement data, review for NIBP trend graph within 24-hour and SpO2 and Pulse rate(PR) trend graph within 20-hour.PerformanceNIBP monitoring■Measurement method: Oscillometry■Measurement mode: manual/auto/continuous.■Auto measurement interval: adjustable from 1 to 90 minutes.■Resolution: 1mmHg.■Accuracy: Maximum Mean deviation≤±5mmHg, Maximum Standard deviation≤8mmHg.■Self-check function.■Overpressure protection: double protection for software and hardware.RangeAdult: Systolic pressure: 40mmHg~270mmHg Mean pressure: 20mmHg~235mmHg Diastolic Pressure: 10mmHg~215mmHgPediatric: Systolic pressure: 40mmHg~200mmHg Mean pressure: 20mmHg~165mmHg Diastolic Pressure: 10mmHg~150mmHgNeonatal: Systolic pressure: 40mmHg~135mmHg Mean pressure: 20mmHg~110mmHg Diastolic Pressure: 10mmHg~100mmHgUpper and lower limit of alarmAdult: Systolic pressure: 40mmHg~270mmHg Mean pressure: 20mmHg~235mmHg Diastolic Pressure: 10mmHg~215mmHgPediatric: Systolic pressure: 40mmHg~200mmHg Mean pressure: 20mmHg~165mmHg Diastolic Pressure: 10mmHg~150mmHgNeonatal: Systolic pressure: 40mmHg~135mmHg Mean pressure: 20mmHg~110mmHg Diastolic Pressure: 10mmHg~100mmHgSpO2 monitoringContinuous real-time measuring.Adopt digital SpO2 technology, which has strong anti-interference capability.Real-time display SpO2, pulse rate, SpO2 Plethysmogram, bar graph, SpO2 and Pulse rate(PR) trend graph.Standard finger-clip probe for adult , binding probe for neonatal is optional.SpO2 MeasuringRange: 35%~100% (Resolution: 1%)Accuracy: ±2% in stage of 70%-100%, and unspecified in stage of less than 70%.Pulse Rate MeasuringRange: 30bpm~250bpm(Resolution: 1bpm)Accuracy: ±2bpm or ±2%, whichever is greater.Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be showncorrectly when pulse-filling ratio is 0.4%, SpO2 error is ±4%; the Pulse rate error is ±2bpm or ±2%, whichever is greater.Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.AccessoriesA power cordA power adapterA SpO2 probeAn adult NIBP cuffAn extending tube for blood pressurePhysical characteristicDimension for product: 190(L)×162(W)×240(H)mmWeight: 1.6kgDimension for packaging: 402(L)×228(W)×320(H)mm Buy safe ProductsThe following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies.If the item is subject to FDA regulation, We will verify your status as an authorized purchaser of this item before shipping of the item. The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 197923, and certified by FDA of United States and CE,TUV of Europe.The Fingertip Pulse Oximeter that is FDA 510K Approved ABOUT US Contec Medical Systems Co., Ltd. (hereinafter referred to as CONTEC) focusing on research, manufacture and distribution of medical instruments, was founded in 1996 as a high-tech company. CONTEC locates in Economic & Technical Development Zone in Qinhuangdao covered an area of 125 acres and building area of over 100000 square meter, which is one of the largest bases for R & D and production of medical devices in China. Contec hopes to cooperate with international companies to supply more innovative design and advanced technology products We sincerely welcome you to become one of our global partners.We are looking forward to establishing a successful business relationship with you. Only English user guide, if you need any other language, please contact us!
Price: 299 USD
Location: Beijing
End Time: 2023-08-14T12:06:44.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 60 Days
Refund will be given as: Money Back
Model: CMS5100
Country/Region of Manufacture: China
MPN: 69450401
Monitor Parameters: Blood Pressure, Blood Pressure - NIBP, O2 - SpO2, Temperature
Brand: CONTEC