Description: CMS50D-BT Pulse Oximeter Instructions Principle of the CMS50D-BT Pulse Oximeter is as follows: Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning & Recording Technology,the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger.The product is suitable for being used in family, hospital, oxygen bar, community healthcare, physical care in sports (It can be used before or after doing sports, and it is not recommended to use the device during the process of having sport) and etc. Major Features Integrated with SpO2 probe and processing display moduleSmall in volume、light in weight and convenient in carryingOperation of the product is simple ,low power consumptionOperation menu for the function settingSpO2 value displayPulse rate value display, bar graph displayPulse waveform displayThe display mode can be changedA pulse rate sound indicationWith measured data overruns limits and low-voltage alarm function,the upper/down alarm range can be adjustableLow-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage,and with alarm functionWith SpO2 value and pulse rate value of storage, the storage data can be uploaded to computersReal-time data can be transmitted to computersRF communication function(option)Connected with an external oximeter probe(option) Main performance Display Mode: 0.96" Dual color OLED displayScreen Resolution: 128*64SpO2 Measuring Range: 0%~100%(the resolution is 1%)Accuracy: 70%~100%: ±2% ,Below 70% unspecified.PR Measuring Range 30bpm~250bpm, (the resolution is 1bpm)Accuracy: ±2bpm or ±2% (select larger)Measurement Performance in Weak Filling Condition:SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.Power Consumption: less than 80mAVoltage:DC 2.6V~3.6VPower Supply:1.5V (AAA size) alkaline batteries × 2Battery working hour: The theoretical number is 32 hours.Safety Type:Interior Battery, BF Type Accessories Sell in standarda hanging ropea user manuala data line Physical Identity Dimension:58.5(L) × 31(W) × 32 (H) mmWeight:About 50g (with the batteries) CertificationCE, FDA Buy Safe Product! The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE:The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, We will verify your status as an authorized purchaser of this item before shipping of the item. The Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 197923, and certified by FDA of United States and by CE,TUV of Europe
Price: 25.99 USD
Location: Elk Grove Village, Illinois
End Time: 2024-08-10T09:06:11.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 60 Days
Refund will be given as: Money Back
Brand: CONTEC
Form Factor: Fingertip
Oximeter Type: Pulse Oximeter without Probe
Model: CMS50D-BT
MPN: Does Not Apply
Included Probe: Adult Finger Probe