Description: Description: Dental Oral implant monitor can be used in oral implant surgery. It can monitor and measure human body's vital signs in real time for patients, especially patients with cardiovascular and cerebrovascular diseases and diabetes, and monitor the changes of life signs in real time, and provide basis for oral implant.Features:High brightness and high resolution display 8 inch color LCD screen ,more comfortable glare7-Channel ECG Waveform display,5 minutes ECG waveform playback, automatic detection of ST segment384 hours trend data memory for all the parameters and dynamic waveform captureCan be arbitrarily set the alarm limit, automatic sound and light alarmAnti-movement, anti-defibrillation, anti electrosurgical interferenceRemote central monitoring network interfaceDrug solubility calculation function, Arrhythmia analysis functionBuilt-in lithium battery, AC and DC, can provide long-term monitoring after power failureWidely used in the Department of internal medicine, Dntal practices (both pediatric and adult), oral surgery centers surgery, operation room,obstetrics and Gynecology, pediatrics, emergency center, ICU, CCU.Standard configuration:ECG, NIBP, SPO2, TEMP, RESP,Technical parameters:ECG Measurement:Leads choices: All, I, II, III, aVF, aVR, aVL. V1--6 chest leads showedGains options: × 1, × 2, × 4, and × 0.5 four trenchesFrequency:diagnosis 0.05 ~ 130HzMonitoring 0.5 ~ 40HzOperation 1~ 20HzCommon-mode signal inhibition:diagnosis > 90 dBMonitoring > 100 dBOperation > 100 dBScan rate: 12.5 mm / S, 25 mm / S, 50 mm / S standard three stalls.HR range:Adult :15 ~ 300bpmInfants / children: 15 ~ 350 bpmHR Accuracy: ± 1 bpmPrecision calibration signal: 1mv(peak, ± 5% accuracy)ST Detection: measurement range (-2.0mV~+2.0mV)Baseline recovery time: < 3 seconds after defibrillationAlarm: Sound and LightPreset heart rate range: (Alarm over preset numerical)Ceiling:40~255 bpm adjustableThreshold: 20~160 bpm adjustableRESP Breath:Breathing frequency range:Adult : 7~120 brPMInfants / children:7~150 brPMAccuracy:± 2brpmGains options: × 1, × 2, × 4, and × 0.5 four trenchesAlarm: Sound and LightAlarm range: (numerical preset alarm over)Ceiling: 10~100 bpm adjustableThreshold: 0 ~99 bpm adjustableNIBP measurement:Technology: OscillometricMode: Manual / automatic / continuousMeasurement units: mmHg / kpaProtection: Double security protectionScope: Pressure Cuffs 0-250 mmHgOvervoltage protection: Double safety protectionAdult Pattern:300 mmHgChildren Pattern:240 mmHgNewborn Pattern:150 mmHgBlood pressure measuring range:AdultSystolic blood pressure: 40~270 mmHgDiastolic blood pressure: 10~215 mmHgPressure on the average: 20~235 mmHgChildrenSystolic blood pressure: 40~200 mmHgDiastolic blood pressure: 10~150 mmHgPressure on the average: 20~165 mmHgNewbornSystolic blood pressure: 40~135 mmHgDiastolic blood pressure: 10~100 mmHgPressure on the average: 20~110 mmHgThe accuracy of blood pressure:The maximum average error amp 5mmHg; maximum standard deviation 8mmHgAlarm: Sound and LightPreset range: report (Numerical exceed preset alarm)Systolic blood pressure maximum: 40~250 mmHg adjustableThreshold: 10~220 mmHg adjustableDiastolic blood pressure ceiling: 20 ~250 mmHg adjustableMinimum standards: 10 ~220 mmHg adjustableSpo2 measurementRange: 70~00%:±2DIGIT 0~69%:Not definedResolution: 1%Pulse frequency: 20~300 times / minAlarm: Sound and LightPreset range: report (Alarm over preset numerical)Ceiling: 20% ~ 100% adjustableThreshold: 10% ~ 99% adjustableTEMP measurement:Technology: thermostat temperature probeMeasuring range: 0°C~45°CTemperature resolution: 0.1%Accuracy: ± 1°CResponse Time: 1sAlarm: Sound and LightPreset range: report (numerical preset alarm over)Maximum: 20.1°C~45 ° C adjustableThreshold: 20°C~44.9°C AdjustablePower:AC power supply: AC 220V, 50Hz. 1A maximum currentTemperature: 5~40°CStorage temperature: -20°C~40°CWorking humidity: ≤85% relative humidity, non-condensingHumidity storage: ≤95% relative humidity, non-condensingAltitude: 86~4106kpa feet (working condition)Whole Power: not more than 70VAPackage Include:1×Dental Patient Monitor1×Cuff for adult1×SpO2 Probe1×5 lead EKG Cable1×Temperature Probe For ECG monitor1×User ManualFDA Statement:The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.This item has been cleaned and treated according to the manufacturer's instructions.Crystal-China-Beijing-86-15140779313 The Fingertip Pulse Oximeter is certified with the US FDA 510K No. K070371, the CE & TUV of Eureope and it is on the Australian Register of Therapeutic Goods (ARTG) with the code 136606. The Powered Surgical Instrument / Speed 808 System is certified with the US FDA 510(k) Number:K132989 The Powered Surgical Instrument / Hair Remove Device is certified with the US FDA 510(k) Number:K180353 The Powered Surgical Instrument / Hair Remove System is certified with the US FDA 510(k) Number:K141973 massager, vacuum, light induced heating / Slimming Treatment Device is certified with the US FDA 510(k) Number:K161892
Price: 419 USD
Location: Los Angeles, California
End Time: 2024-11-27T23:49:00.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Brand: Carejoy
Standard configuration: ECG, NIBP, SPO2, TEMP, RESP
Technology: Digital
MPN: Does not apply
Monitor Parameters: Blood Pressure - NIBP, ECG
Gains options: × 1, × 2, × 4, and × 0.5 four trenches
Intended Use/Discipline: Cardiology
Precision calibration signal: 1mv(peak, ± 5% accuracy)